FLARIS Blade - New DMX Channels for Firmware v2.13 FLARIS Blade - New DMX Channels for Firmware v2.13

FLARIS Blade - New DMX Channels for Firmware v2.13

Support Team Support Team

No: V-TSB110425

Date: Nov 4th, 2025

Model: FLARIS Blade [RGBW]

New Firmware Version 2.13 + New DMX Modes 

Volux has introduced a major firmware update for Flaris Blade, which implements key functional improvements based on extensive field testing and user feedback to meet professional demands and provide an optimal operating experience. 

Fixture firmware Version 2.13 adds independent Shutter/Strobe control between outer RGBW color segments and center cold white segments. While fixture continuity and profile consistency remain a key part of our product philosophy, this update requires an inevitable change to the DMX channel index and personality modes. 

Version 2.13 implements the addition of a 14-channel mode and replacement of the 89-channel mode with a new 90-channel mode. 13-channel and 64-channel modes remain unchanged as of this firmware version. This update also includes key functional feature updates, including Pixel Invert control. 

All customers are encouraged to update to v2.13 as soon as possible. Please contact Volux Support for update instructions. 

Channel Mode Firmware Version Shutter Control Backwards Compatible
13ch Mode v2.12, v2.13 or Higher Single Shutter Control Yes
14ch Mode v2.13 or Higher Dual Shutter Control No
64ch Mode v2.12, v2.13 or Higher No Shutter Control Yes
89ch Mode v2.12 or Lower Single Shutter Control N/A
90ch Mode v2.13 or Higher Dual Shutter Control No

Both new and legacy DMX profiles and DMX reference charts will remain published as part of this transition. 

Legacy Version

New Version (v2.13 or Higher)

DMX Reference Chart v1.0.0 DMX Reference Chart v2.0.0
User Manual + Menu Map v1 New User Manual + Menu Map v2
MA2 Fixture Share (13ch, 64ch, 89ch) MA2 Fixture Share (13ch, 14ch, 64ch, 90ch)
MA2 Fixture Share (13ch, 64ch, 89ch) MA3 Fixture Share (13ch, 14ch, 64ch, 90ch)
GDTF Share (v1.2) GDTF Share (v4.0)

Flaris Blade Firmware Update Log

Important Notes:

  • Pre-programmed shows using 89ch mode should remain on lower versions. Functionality cannot be guaranteed with v2.13 cannot be guaranteed. 
  • Downgrading from v2.13 cannot be guaranteed. 
  • Flaris Blade models produced prior to Jan 2026 require a USB-to-DMX updater tool to update. Please contact Volux Support for more information. 

Should you have any questions or concerns, please contact Volux Support via Ticket Submission.